SiteScope User's Guide


Deploying Siebel Gateway Server Solution Templates

The SiteScope Siebel Gateway Server Solution allows you to monitor the availability and server statistics for Siebel Gateway servers installed on Windows platforms.

Usage Guidelines

This solution template will deploy a set of monitors that test the health, availability, and performance of Siebel Gateway Servers. You can use this solution template to deploy monitors for server-wide resources and metrics

Deploying the Siebel Gateway Server Solution Template

You use the following steps to deploy the Siebel Application Server Solution Form.

To deploy the Siebel Gateway Server Solution Template:

  1. Create a SiteScope monitor group into which you will deploy the Siebel Gateway Server Solution Template. This should be the same group or a subgroup associated with the group where you deploy the other Siebel solution templates.
  2. Within the monitor group, click the Solution Template link below the Monitor Detail Table to add a solution template to the group. The Solution selection screen opens.
  3. Click the Siebel Gateway Server link in the table of solutions. The Solution Properties for Siebel Application Server form opens.
  4. Complete the properties needed for SiteScope to connect to the Siebel Application Server in the form as described in the following sections.
  5. Click the Show Applications button. SiteScope queries the Siebel Gateway Server and retrieves a list of modules that are available on the server. The module selection window opens with a reduced listing of modules.
  6. Select the modules and parameters that you want to monitor. See the section on Selecting Modules for Monitoring for more information on the module types.
  7. After selecting the desired modules, scroll down in the module selection window and click the Select Modules button. The selection window closes and the Solution Properties for Siebel Application Server form is displayed populated with a check list of the selected modules.
  8. If necessary, use the check boxes in the selected modules list to deselect any parameters that you do not want to monitor. Click the Submit button to continue. The Property and Syntax Check screen opens. See the section on Verifying Monitor Values for more information.
  9. Click the Create Solution button to initiate the deployment of the monitors. A monitor creation screen is displayed.

    As the monitors are created, the monitor type and name are displayed along with messages of any errors found. A "success" message is shown if the monitors are created successfully. The process does not run the monitor.

    Note: Errors detected during the creation of monitors using a solution template are independent of the status returned when the individual monitors are run. This means that the monitors may be created successfully but that the configuration settings may be incorrect or that the system being monitored is unavailable.

  10. After the monitors have been created, you can select the Return link to return the group detail page to view the status of the monitors.

After deploying the monitors, you should review the Error and Warning status thresholds and adjust them according to the importance of the monitored element. You should also create alerts and associate them to the newly created monitors to provide notification when an error is detected.

Note: Solution Templates do not configure any automated alerts for the monitors created. You must create and associate one or more alert definitions to the monitors or monitor groups created by solution templates.

Settings in the Siebel Gateway Server Solution Form

The following describes the settings on the Siebel Gateway Server Solution Form:

Server
Enter the name of the server where the Siebel Gateway Server is running. Do NOT enter backslashes (\\) that indicate a UNC path as part of the name of the server.

Siebel Disk
Enter the disk drive where the Siebel gateway server is running.

Siebel Directory
Enter the path to the Siebel Directory. This directory should contain at least an Admin Console installation.

Verifying Monitor Values

During the deployment of the Solution template, each monitor configuration is displayed in the Property and Syntax Check table. The solution type is displayed above the table. The first column shows the monitor's property name. The next column shows the value for that property. Values that contained variables are shaded with green. Values that are not affected by variables show no shading. The final column is for displaying errors that SiteScope has found while verifying the values. Errors are shaded in red. Errors should be corrected before proceeding to the next step, but SiteScope does not require it, however doing so may create monitors that do not function properly.

The following is an example section from the Property and Syntax Check page for a Siebel Gateway Server Solution Template.

Property and Syntax Check for Solution:Siebel Gateway Server

Errors were found with this Solution set. The errors should be corrected before creating these monitors otherwise invalid monitors may be created.


Monitor Type: CPUMonitor     Monitor Name: CPU Utilization on \\\\servername

PropertyValue Property or Syntax Errors
frequency600 
machine\\\\servername 
nameCPU Utilization on \\\\servername 

Monitor Type: DiskSpaceMonitor     Monitor Name: Disk Space: C: on \\\\servername

PropertyValue Property or Syntax Errors
diskC: 
frequency600 
machine\\\\servername 
nameDisk Space: C: on \\\\servername 

Monitor Type: DirectoryMonitor     Monitor Name: Directory: \\\\servername\sea2000\gtwysrvr\LOG

PropertyValue Property or Syntax Errors
frequency600 
path\\\\servername\sea2000\gtwysrvr\LOG 
nameDirectory: \\\\servername\sea2000\gtwysrvr\LOG 
_path 

Monitor Type: ServiceMonitor     Monitor Name: Service: Siebel Gateway Name Server Service on \\\\servername

PropertyValue Property or Syntax Errors
frequency600 
serviceSiebel Gateway Name Server 
machine\\\\servername 
nameService: Siebel Gateway Name Server Service on \\\\servername